Recent Calls
Tue. Jan 14th 2014
MVA Pin Job Monroe Ansonville Rd

On Tuesday Jan 14th @ 3:33pm. Beaver Lane Rescue 8 was dispatched to assist Wingate FD. With a MVA confirmed pin job. Rescue ...

Read more »
Sat. Apr 6th 2013
WORKING HOUSE FIRE IN BEAVER LANES SECOND DUE

On Friday April 5th @10:11 am. Beaver Lane was dispatched on mutual aid.To a house fire with Wingate VFD. First uni...

Read more »
Sun. Jan 27th 2013
WORKING HOUSE FIRE EAST UNION ST MARSHVILLE

On Saturday Jan 26 @ 2:38 am. Beaver Lane and Wingate Fire were dispatched to a house fire on East Union St In  Mar...

Read more »
News Headlines
Sun. Oct 21st 2012
Patient Vehicle Movement & Associated Tactics Class

On Sept 29-30. Beaver Lane hosted a vehicle extrication class. 30 students from 8 departments came and spent 2 days. Learning...

Read more »
Fri. Jul 29th 2011
Beaver Lane installs our first Knox Box key vaults.

Beaver Lane started a new program today 7/29/2011 aimed at adding safety and rapid access to our local businesses.  We i...

Read more »
Fire Glossary
Click a letter to view all entries that begin with that letter.
A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
31 entries the in Fire Glossary beginning with "A"
Above-ground storage tank
Storage tank that is not buried. Compare Underground storage tank. Unburied tanks are more prone to physical damage, and leaks are released to the air or ground, rather than the soil surrounding a buried tank.
Accelerant
Flammable fuel (often liquid) used by some arsonists to increase size or intensity of fire. May also be accidentally introduced when HAZMAT becomes involved in fire.
Accelerator (also exhauster)
Portion of dry-pipe system that bleeds air or shunts air pressure below the clapper valve when sprinkler pipe pressure drop is sensed, thus speeding operation of the valve to fill the system with water.
Accountability
The process of emergency responders (fire, police, SAR, emergency medical, etc...) checking into and making themselves announced as being on-scene during an incident to an incident commander or acountability officer. Through the accountability system, each person is tracked throughout the incident until released from the scene by the incident commander or accountability officer. This is becoming a standard in the emergency services arena primarily for the safety of emergency personnel. This system may implement a name tag system or personal locator device(tracking device used by each individual that is linked to a computer).Willoughbyccfd5 23:52, 3 December 2006 (UTC)
Adapter
Plumbing accessories for connecting hoses and pipes of incompatible diameter, thread, or gender. See also reducer, increaser, double male, double female, water thief. May contain combinations, such as a double-female reducer. Adapters between multiple hoses are called wye, Siamese, or distributor, which see below.
Aerial apparatus
Fire truck having an attached extension ladder, nozzle, man-lift-bucket, or similar device raised using power from the truck. May also carry other portable ladders and tools.
Aerial canopy
Fuel type comprised of trees having few low branches, making it less susceptible to ignition by low-intensity fires.
Aerial firefighting (or air attack)
Use of aircraft in support of ground resources to combat wildfires, often most effective in initial attack in light fuels.
Air drop
Delivery of supplies or retardant from the air. Supplies can be dropped by parachute. Retardant is dropped in a single salvo, or one or more "trails", the size of which is determined by the wind and the volume speed and altitude of the airtanker (usually no less than 200 feet above the drop zone).
Air monitoring meter
Electronic device for measuring the presence of one or more chemicals in air, such as oxygen, carbon monoxide, hydrogen sulfide or volatile organic compounds; may have preset danger threshold alarms.
Air operations
Group tasked with coordinating aerial-based observation, supply, rescue and suppression at a wildfire.
Air Tactical Group Supervisor or Air Attack
Coordinates air resources for attack of a fire.
Airbags
(1) inflatable device used for lifting or spreading; (2) vehicle safety device with potential explosion hazard during vehicle extrication if not already blown.
Airpack
Jargon for self-contained breathing apparatus (SCBA).
Airtanker
Fixed-wing aircraft certified by FAA as being capable of transport and delivery of 600 to 3,0000 gallons of water or other liquid or powder fire retardants. Formerly referred to as borate bombers" before borate-based retardants became less desirable. Often accompanied by a spotter plane.
Alarm
(1) system for detecting and reporting unusual conditions, such as smoke, fire, flood, loss of air, HAZMAT release, etc; (2) a specific assignment of multiple fire companies and/or units to a particular incident, usually of fire in nature; (3) centralized dispatch center for interpreting alarms and dispatching resources. See fire alarm control panel.
All companies working
Status report at fire scene indicating that available manpower is busy, and more resources may become necessary if incident is not controlled soon.
Ammonium nitrate
Component of ANFO; contents of two ships that exploded in Texas City Disaster, killing over 500 people, including all 28 volunteer firefighters at the scene.
Anchor point
An advantageous location, usually a barrier to fire spread, from which to start constructing a fireline. The anchor point is used to minimize the chance of being flanked (or outflanked) by the fire while the line is being constructed.
ANFO
Ammonium Nitrate Fuel Oil combination making a high explosive.
Apparatus
A term usually used by firefighters describing a piece of equipment, usually a company vehicle.
Apparatus
Fire engines, trucks, tankers, and combinations; can also refer to other equipment such as the SCBA.
APW
Air-pressurized water fire extinguisher, partially filled with water and then pressurized with an air pump; popular in the US in the 2 1/2-gallon size, rated 2A.
Aqueous Film-Forming Foam (AFFF)
(pronounced "A-Triple-F", also called "Class A") bubbles that act as surfactant to coat and penetrate ordinary fuels (e.g., wood, paper) to prevent them from burning at normal temperatures; also used on Class B" (oil/gasoline) fires to spread a non-volatile film over the surface of the fuel. Applied using eductor or Compressed air foam system (CAFS) and pumped through firehose to a foam nozzle (or sometimes a less-effective fog nozzle).
Arson
The crime of maliciously (or perhaps recklessly) setting fire to property, especially a dwelling. Punishable in various degrees, depending upon the circumstances. Occasionally occurs as a psychotic act of a mentally ill firefighter.
Attack hose
(Attack Line) A use classification of a fire fighting hose connected to output of a pump or other pressure source (e.g., gravity). Firehose used to apply water or other fire fighting agent directly to a fire or burning substance. Typically of 2 1/2 inches (65 mm) diameter or less.
Attic ladder
Narrow, collapsible ladder used to access an attic space via a scuttle hole, which are often found in closets and other narrow passages. Also known as a closet ladder.
Authority Having Jurisdiction (or AHJ)
Organization or agency with legal authority over a given type of incident (e.g, fire, EMS, SAR, arson, HAZMAT); may change or overlap as incident changes, as where fire becomes arson investigation once danger is over, or Motor Vehicle Accident becomes police business after vehicle extrication, fire, and HAZMAT issues are complete.
Autoextended fire
Structure fire that has gone out a window or other opening on one floor and ignited materials above, on another floor or other space (attic, cockloft).
Automatic sprinkler
System of valves and pipes for automatically directing water to a fire when it is detected. May be normally pressurized with water (wet") or with air ("dry") depending upon the application. When a sprinkler-head (or sensor) detects fire/heat the valve opens releasing the water (hopefully onto the fire).
31 entries the in Fire Glossary beginning with "A"
Upcoming Events
Every 2nd Tuesday
7:00pm
Every 3rd Tuesday
7:00pm
Every 1st Tuesday
7:00pm
Picture Gallery
Website Search
Apparatus Gallery
Recent Call Volume
 FireEMS
Jun-11136670
Dec-1075 
Nov-1067 
Oct-1070 
Sep-1073 
Aug-1061 
Jul-101956
Jun-101844
May-101336
Apr-102035
Mar-102033
Feb-102330
Total595904

Call Volume History

Contact Information
Beaver Lane Volunteer Rescue and Fire Department Inc.
310 Olive Branch Street
Marshville, NC 28103
Non-Emergency: 704-624-5550
Emergency: 911
Member Login
Birthdays for December